• Digital Lubrication Oil Flow Meter
  • Digital Lubrication Oil Flow Meter
  • Digital Lubrication Oil Flow Meter
  • Digital Lubrication Oil Flow Meter
  • Digital Lubrication Oil Flow Meter
  • Digital Lubrication Oil Flow Meter

Digital Lubrication Oil Flow Meter

After-sales Service: Manual Instruction
Warranty: 1 Year
Accuracy: ≤±0.1%
Main Application: Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size: DN5-10
Application: Industrial Production
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
Y37713-M
Type
Volume Type Flow Meter
Measuring Media
Liquid
Certification
CE, RoHS, ISO
Net Weight
1.5kg
Gross Weight
2kg
Flowrate
0-18liters/Min.
Transport Package
20PCS/Box
Specification
37*19.5*12cm
Trademark
yaojienter
Origin
China
Production Capacity
100K/M

Product Description


Digital oil flowmeter suitable for the lubrication oil flow meter guns and suitable for metering the engine oil,motor oil,freeze oil,hydraulic oil and all kinds of lubrication oil...

product Introduction
 This product is composed of three parts: the grease gun ,flow meter, the pipeline.It can measure low, medium and high viscosity and  non-inflammable fuel oils precisely. The microprocessor's electronic system has display control and adjusting  function. It was one kind of high accuracy measure grease gun which integrates with oval gear flow meter..

Product characteristic
1,The measurement accuracy up to ± 0.3%
2,The power consumption is extremely low, it will become power down mode if does not work. The standby time is 10 years .Even in normal circumstances the lifetime of batteries can be 5-year ,about 800,000 liters .
3,It has a fixed memory to save the overall to refuel the data,it can preserve the total amount and primary parameters even if the power interrupts completely long time.

Technical parameter
1, flow range: 2-18L/min.
2,work pressure :0.05-0 .7 Mpa
3,Inlet and outlet joint: 1 / 2''Bsp
4, Medium viscosity :10-5000 mPas
5, Operating temperature: -5 ºC -60 ºC
6, Indicating the unit: liters (quarts, pints, gallons)

Oil table structure
       
            Table positive map                     Table opposite map
  1. Meter appearance
  2. 4 indicate unit: L, PT, QT as well as GAL
  3. RESET key :Starting or Clear
  4. TOTAL key :Display the total
  5. Display signals of low power
  6. The screen
  7. Protective cover
  8. Parameter setting keys

Working Principle
  The measurement system is based on the bore of gun which contains two elliptical gears. The gear will rotate when the oil flows through bore of gun. The flow of oil is the same at each rotation.When gears rotate, the generated pulse signal will be recorded to Processes by a microprocessor. The magnetic coupling function between  gear with magnet and magnetic switch out of the bore of gun not only guarantees the bore of gun leak-proof quality,but also ensure the pulse which produced by gear rotation will transmit to the Microprocessor on circuit board.The microprocessor has been converted the pulse into the volume of fuel by adjusting parameters properly and displayed on the screen.
  The measurement grease gun is adjusted with 10W-40 oil before leaving the factory. Each one has primary parameter. It can be adjusted on spot and would maintain the best function that can be used to measure the volume of oil if needs. Please adjust on spot if operators want to measure precisely as the oil viscosity of factory may be different.

Adjust parameters methods
  1,Inject oil into a standard vessel or oil pot till 4. 00 liters (actual value),the meter will show 4.07 (show value). Attention: It can't allow air into the oil meter during the process of injecting oil.
  2,Press the left key(TOTAL) first and then press the right key (RESET), not exceed 3S. If the meter show the primary parameters is 3.4567, write it down on notebook.
  3,Accurate parameter: Actual value (4.00 liters) ÷ Show value of (4.07) Primary parameter (3.4567) = standard parameter (3.3972) .
  4,Loosen 3 screws that connect the cover and measurement of body, take away the watch cover, press the SET key on the reverse of the watch cover 3 seconds,the screen will show primary parameter and the letter "L" flash, it enter adjusting parameter mode.
  5,Presses the left key (TOTAL) when it moves 1 digit after the decimal point, the number will flash then press the right key (RESET) to increase the number up to "3".
  6,Presses the left key (TOTAL) when it moves 2 digit after the decimal point, the number will flash then press the right key (RESET) to increase the number up to "9".  7,Presses the left key (TOTAL) when it moves 3 digit after the decimal point, the number will flash then press the right key (RESET) to increase the number up to "7".
  8,Presses the left key (TOTAL) when it moves 4 digit after the decimal point, the number will flash then press the right key (RESET) to increase the number up to "2".
  9,Press left key (TOTAL), the letter "L" will flash, please press right key (RESET) to change the Unit into PT, QT or GAL if needs. Usually it can be omit this step as the primary unit has been set to " L "
  10,The present parameter has adjusted as the calibration parameter 3.3972,then press the key on the reverse of the meter cover 3 second till the parameter on the screen flashes, it shows no signals then presses the right key (RESET) to turn on the meter. The parameter adjustment finished .

Maintenance
This product needs regular maintenance:
  1. Please replace new battery if battery signal twinkle. The battery type is CR1/2AA.6127 3V/950aAH.
  replacement method battery is :
takes away the meter cover and protection cover ,replace the battery directly. Please pay attention to the battery's polarity .
  1. Clear interior of the bore of gun
 steps are as following :
Put the grease gun on a clean soft cloth,twist off  6 screws on the seal-oil bottom cover ,and take away the bottom cover and the seal ring,takes out the gear, clear the place that need clean pay attention to not destroy the gear and the survey cavity chest where the left gear loads with the magnet, and it forward adown with the magnet It shows in right picture.
  The left gear must be installed vertically with the right gear.Make sure the gear turns freely before cover .
  1. Please close the gas source when current capacity drops obviously,buckle the oil gun main trigger and release press completely,then unload the oil hose from the aluminum alloy  handle, take out the strainer, install it after careful clean.
  2. The joint between the inlet oil hose and the oil gun is not suitable to twist too tightly to avoid to damage the strain,Generally screw tightly by hand, then use the spanner to twist the half-turn.
  3. when use or maintenance , please get light.Please lay aside in a steady place to prevent injuring by falling down after use.
  4. If it does not work, please release the pressure by buckling the oil gun trigger.
  5. It should buckle the main trigger first if inject oil.
  6. measurement of grease gun at least every six months to a self-calibration ,in the peculiar circumstance calibrates the number of times to increase .





Failure processing
Breakdown phenomenon Breakdown reason Processing method
The flux diminish or not leave the oil Filter jamming Cleaning Filter
The flux is normal, but has not show the measurement data About the gear installs in reverse reshipment Gear
Gear Failure instead gear
inductor damage instead inductor
Surveys Inaccurate The parameter is inaccurate Inspects and calibrates the parameter
The pump suction air, the fuel oils have been insufficient Supplements the fuel oils
display screen no show battery start Reinstall  battery
The battery capacity uses up instead battery

Digital Lubrication Oil Flow MeterDigital Lubrication Oil Flow Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now